The method of replacing the cooling fan and the judgment of the speed value


Release time:

2020-03-14

Cooling fan replacement method Cooling fan, the use of more than three years or so, will often be damaged or heat dissipation function damage because of the ash, then we can change a new cooling fan to ensure the normal use of electrical appliances, so how to replace the radiator correctly:

Cooling fanMethod of replacement
Cooling fan, the use of more than three years or so, will often be damaged or heat dissipation function damage because of the ash, then we can change a new cooling fan to ensure the normal use of electrical appliances, so how to replace the radiator correctly:
1. Open the CPU cooler and check whether the accessories are complete and whether the parameters match. The general composition has the fan, the base, the clip, the heat dissipation silica gel these several major parts.
2. Put the white clip into the base slot first, then put the black clip into the base to complete the installation of the base.
3. Spread the heat dissipation silica gel evenly on the radiator and CPU, and insert the base into the motherboard card slot to fix the position.
4. Check the angle and position, and simulate the installation in advance. If it is not suitable, adjust it in time.
5. Put the radiator into the base, and at the same time use the clips on both sides of the radiator to clamp the buckle on the base. At the same time, the power cord is inserted into the corresponding interface of the motherboard, and the installation can be completed to boot.
 
Judgment of Speed Value of Cooling Fan
Cooling fans are usually divided into the following three categories:
1. Axial flow: the direction of the airflow outlet is the same as the axis direction.
2. Centrifugal type: the use of centrifugal force will flow out along the blade.
3. Mixed flow type: has the above two air flow modes.
Speed refers to the speed of the fan rotation, usually in 1 minutes to calculate the number of turns, referred to as: rpm. The rotating speed is related to the number of turns of electromechanical winding, wire diameter, outer diameter and bottom diameter of fan blade impeller, blade shape and bearing used, etc. The rotating speed increases and the air volume increases accordingly.
 
The size of the speed value represents the size of the air volume to a certain extent. When the conditions are certain, the greater the speed, the noise and vibration will increase accordingly. Therefore, when the air volume meets the heat dissipation requirements, low-speed fans should be used as much as possible. General speed (taking DC axial fan as an example):2510 fan 7000~12000rpm;3010 fan 5000~9000rpm;4010 fan 5000~7000rpm;5010 fan 3500~5000rpm;6025 fan 2600~4500rpm;7025 fan 2400~3600rpm;8025 fan 2000~3500rpm;9225 fan 1600~3100rpm;12025 fan 1500~2500rpm;12038 fan 2000~3200rpm.
The fan speed can be tested by BIOS when starting the computer, or by other monitoring software that comes with the motherboard; it can also be tested by the speed tester.
 
Shenzhen Jiangshanlai Electronic Technology Co., Ltd. is a professional brushless DC motor, DC cooling fan, DC brushless fan, DC bracket fan, supercharged cooling fan, micro cooling fan, DC cooling fan, DC blower and non-standard customized fan A large-scale enterprise integrating R & D, manufacturing, sales and service, DC fan manufacturer, DC fan supplier wholesale. Products sell well in Guangdong, Shenzhen, Guangzhou, Dongguan, Fujian, Zhejiang, Jiangsu and other places.

Related News

Understanding the Benefits and Applications of the 93x93x30mm DC Blower in Industrial Ventilation

The 93x93x30mm DC blower is a compact yet powerful component widely used in the industrial equipment sector, particularly in air conditioning, refrigeration, and ventilation systems. This blower is designed to provide efficient airflow, making it an ideal choice for applications where space is limited but effective cooling and ventilation are crucial. One of the key features of the 93x93x30mm DC b

2026-08-02

Understanding the Mechanics of the 70x70x15mm Mini DC Blower: A Comprehensive Guide

Understanding the Mechanics of the 70x70x15mm Mini DC Blower Table of Contents 1. Introduction to Mini DC Blowers 2. Design and Structure of the 70x70x15mm Mini DC Blower 3. Mechanical Functionality and Performance 4. Applications of the 70x70x15mm Mini DC Blower 5. Advantages of Using a Mini DC Blower 6. Installation and Maintenance Guidelines 7. Troubleshooting Commo

2026-07-26

Understanding the Benefits of 60x60x28mm High Airflow Blower Fans for Industrial Cooling Solutions

In the realm of industrial equipment and components, especially within the cooling and ventilation sector, the importance of efficient airflow cannot be overstated. One key player in this domain is the 60x60x28mm high airflow blower fan. These fans are designed to deliver optimal performance while maintaining a compact form factor, making them ideal for various applications across industries. The

2026-07-19