[Heat dissipation knowledge] DC fan, heat dissipation fan test method steps
Release time:
2019-03-26
1. Current: The current is measured after continuous rotation for 3 minutes 2. Speed: the rate is measured after 3 minutes of continuous rotation 3. Starting voltage: the voltage that can start the fan operation after turning on the switch "ON" 4. Input power: The input power is measured after 3 minutes of continuous rotation 5. Lock current: can lock the fan of the machine, lock the current in the fresh air lock machine 3 minutes 6. Air flow data and pressure data are measured according to "AMCA standard" or DIN24163 rules. The data are measured in double pressure chambers, and the pressure data on each side of the pressure chamber need to be measured. 7. Noise standard: The noise standard test refers to the DIN45635 standard, and the measurement is carried out in the soundproof room. The microphone is placed at one meter of the fan.
DC Fan1. Cooling fan test method steps
1. Current: current in continuous rotation3Measurement after minutes
2. Speed: speed in continuous rotation3Measurement after minutes
3.Starting voltage: open switch"ON"After, the voltage that can start the fan operation
4.Input power: input power in continuous rotation3Measurement after minutes
5.Lock current: can lock the fan of the machine, lock the current lock the machine in the fresh air3Minute determination
6.Air flow data and pressure data are determined according to"AMCAstandard "orDIN24163Rules, the data determination is carried out in the double pressure chamber, and the pressure data on each side of the pressure chamber needs to be determined.
7.Noise standard: noise standard test referenceDIN45635Standard, the measurement is carried out in a soundproof room, and the microphone is placed one meter from the fan