Blog

[Do you know about heat dissipation] What are the technical specifications of DC fans


Release time:

2019-07-22

1. Fan test method: 1.1 current: current is measured after continuous rotation for 3 minutes. 1.2 speed is measured after continuous rotation for 3 minutes. 1.3 starting voltage is measured after continuous rotation for 3 minutes. voltage that can start fan operation 1.4 input power is measured after continuous rotation for 3 minutes. 1.5 locking current is measured after continuous rotation for 3 minutes. fan that can lock the machine, lock current Lock the machine in fresh air for 3 minutes 1.6 Air flow data and pressure data are measured according to "AMCA standard" or DIN24163 rules, the data are measured in double pressure chamber, and the pressure number on each side of the pressure chamber needs to be measured.

1. Fan test method:
1.1 current: the current is measured after continuous rotation for 3 minutes
1.2 speed: the speed is measured after continuous rotation for 3 minutes
1.3 starting voltage: the voltage that can start the fan operation after opening the switch "ON"
1.4 input power: The input power is measured after continuous rotation for 3 minutes
1.5 locking current: the fan that can lock the machine, the locking current is measured in the fresh air for 3 minutes
1.6 Air flow data and pressure data shall be measured according to "AMCA standard" or DIN24163 rules. The data shall be measured in double pressure chamber, and the pressure data on each side of the pressure chamber shall be measured.
1.7 Noise standard: The noise standard test refers to the DIN45635 standard, the measurement is carried out in a soundproof room, and the microphone is placed at one meter of the fan
2. Fan protection test:
 
2.1. swivel lock protection
2.1.1 Several fan blades are connected together to fix and restrict its rotation. If the fan and electronic components are not damaged and the components restricting rotation are released, the fan can automatically restart its rotation.
2.1.2 For fans with small current or with Auto start function, lock the fan blades in the power-on rotation state. After 72 hours, loosen the locked fan blades, and the fan will automatically restart immediately, proving that the fan is normal.
2.1.3 Fans with high current or without Auto start function cannot be locked for a long time, otherwise the fan will be overheated and damaged.
 
2.2 polarity protection
Under normal voltage conditions, if the fan is powered on for 15 minutes with the reverse power supply, and then press the normal two poles to connect again after the power is off, all functions will be normal
 
2.3. Free Fall
The monomer is dropped from an altitude of 600mm to a 30mm thick board. Any one and one corner of the 6 surfaces of the fan can withstand the drop test and confirm that there is no damage.
 
2.4. Insulation impedance
Under the condition of 500V DC, the positive resistance of the outer frame and the lead shall not be less than 10MΩ.
 
2.5. Insulation strength
Under the condition of 5mA leakage current and AC500V for 60 seconds, there is no abnormality between the outer frame of the fan and the wire, which proves that the insulation is good.
 
The above is a brief introduction to the DC fan technical specifications. Shenzhen Jiangshanlai Electronic Technology Co., Ltd. is a company specializing in brushless DC motors,DC cooling fan , DC brushless fan, DC bracket fan, booster cooling fan, micro cooling fan, DC cooling fan, DC blower, and non-standard fan customization, research and development, manufacturing, sales and service in one of the large enterprises, DC fan wholesale manufacturers, DC fan suppliers. Products sell well in Guangdong, Shenzhen, Guangzhou, Dongguan, Fujian, Zhejiang, Jiangsu and other places.
If there is a need, you can consult us.

Related News

Understanding the Benefits and Applications of the 93x93x30mm DC Blower in Industrial Ventilation

The 93x93x30mm DC blower is a compact yet powerful component widely used in the industrial equipment sector, particularly in air conditioning, refrigeration, and ventilation systems. This blower is designed to provide efficient airflow, making it an ideal choice for applications where space is limited but effective cooling and ventilation are crucial. One of the key features of the 93x93x30mm DC b

2026-08-02

Understanding the Mechanics of the 70x70x15mm Mini DC Blower: A Comprehensive Guide

Understanding the Mechanics of the 70x70x15mm Mini DC Blower Table of Contents 1. Introduction to Mini DC Blowers 2. Design and Structure of the 70x70x15mm Mini DC Blower 3. Mechanical Functionality and Performance 4. Applications of the 70x70x15mm Mini DC Blower 5. Advantages of Using a Mini DC Blower 6. Installation and Maintenance Guidelines 7. Troubleshooting Commo

2026-07-26

Understanding the Benefits of 60x60x28mm High Airflow Blower Fans for Industrial Cooling Solutions

In the realm of industrial equipment and components, especially within the cooling and ventilation sector, the importance of efficient airflow cannot be overstated. One key player in this domain is the 60x60x28mm high airflow blower fan. These fans are designed to deliver optimal performance while maintaining a compact form factor, making them ideal for various applications across industries. The

2026-07-19