Blog

[Know about Heat Dissipation] Talking about DC DC Heat Dissipation Fan


Release time:

2019-09-02

DC DC fan input is DC, the general DC voltage is: 3V, 12V,24V,32V,48V,5V,60V,25.5V,42V,18V,15V. The operation principle is based on Ampere's right-hand rule. When the conductor passes current, a magnetic field will be generated around it. If the conductor is placed in another fixed magnet, suction or repulsion will be generated, causing the object to move. Inside the fan blade of the DC fan, a rubber magnetic strip that has been filled with magnetism before is attached. Around the silicon steel sheet, two sets of coils are wound on the axis part, and a Hall induction component is used as a synchronous detection device to control a set of circuits, which makes the two sets of coils wound on the axis work in turn. The silicon steel sheet produces different magnetic poles, which generate attraction and repulsion with the rubber magnet. When the suction repulsion is greater than the static friction of the fan, the fan blades naturally rotate. Because the Hall induction component provides the synchronization signal, the fan blade can continue to operate. As for its direction of operation, it can be determined according to Flemming's right-hand rule.

  DCDC FanThe input is DC, the general DC voltage is: 3V, 12V,24V,32V,48V,5V,60V,25.5V,42V,18V,15V. The operation principle is based on Ampere's right-hand rule. When the conductor passes current, a magnetic field will be generated around it. If the conductor is placed in another fixed magnet, suction or repulsion will be generated, causing the object to move. Inside the fan blade of the DC fan, a rubber magnetic strip that has been filled with magnetism before is attached. Around the silicon steel sheet, two sets of coils are wound on the axis part, and a Hall induction component is used as a synchronous detection device to control a set of circuits, which makes the two sets of coils wound on the axis work in turn. The silicon steel sheet produces different magnetic poles, which generate attraction and repulsion with the rubber magnet. When the suction repulsion is greater than the static friction of the fan, the fan blades naturally rotate. Because the Hall induction component provides the synchronization signal, the fan blade can continue to operate. As for its direction of operation, it can be determined according to Flemming's right-hand rule.
According to the working principle, we can know that there are permanent magnet bars in the rotor of the DC cooling fan but not the AC cooling fan, and the DC fan has PCB board but the AC fan does not. In terms of frame blades, the fan frame and fan blades of the DC fan are generally made of plastic materials, mainly PBT materials, which are usually applied in the form of 30% fiber addition in terms of parameters. The power consumption of the DC fan is much smaller than that of the AC, the speed that the AC cooling fan can achieve is much smaller than that of the DC cooling fan, but the price is more expensive than the DC cooling fan.
 The above is the use of cooling fan noise and noise difference judgment small knowledge sharing. Shenzhen Jiangshanlai Electronic Technology Co., Ltd. is a large-scale enterprise specializing in the customization, research and development, manufacturing, sales and service of DC brushless motors, DC cooling fans, DC brushless fans, DC bracket fans, pressurized cooling fans, micro cooling fans, DC blowers, and non-standard fans, DC fan wholesale manufacturers and DC fan suppliers. Products sell well in Guangdong, Shenzhen, Guangzhou, Dongguan, Fujian, Zhejiang, Jiangsu and other places.
If there is a need, you can consult us.

Related News

Understanding the Benefits and Applications of the 93x93x30mm DC Blower in Industrial Ventilation

The 93x93x30mm DC blower is a compact yet powerful component widely used in the industrial equipment sector, particularly in air conditioning, refrigeration, and ventilation systems. This blower is designed to provide efficient airflow, making it an ideal choice for applications where space is limited but effective cooling and ventilation are crucial. One of the key features of the 93x93x30mm DC b

2026-08-02

Understanding the Mechanics of the 70x70x15mm Mini DC Blower: A Comprehensive Guide

Understanding the Mechanics of the 70x70x15mm Mini DC Blower Table of Contents 1. Introduction to Mini DC Blowers 2. Design and Structure of the 70x70x15mm Mini DC Blower 3. Mechanical Functionality and Performance 4. Applications of the 70x70x15mm Mini DC Blower 5. Advantages of Using a Mini DC Blower 6. Installation and Maintenance Guidelines 7. Troubleshooting Commo

2026-07-26

Understanding the Benefits of 60x60x28mm High Airflow Blower Fans for Industrial Cooling Solutions

In the realm of industrial equipment and components, especially within the cooling and ventilation sector, the importance of efficient airflow cannot be overstated. One key player in this domain is the 60x60x28mm high airflow blower fan. These fans are designed to deliver optimal performance while maintaining a compact form factor, making them ideal for various applications across industries. The